Control Pin
Operation
Sync Input
Pin 4 is the
Sync Input. The power hybrid operates at approximately 180 kHz and
may be synchronized to frequencies from 190 to 210 kHz. The sync
input pulse must meet the following levels as shown in the diagram.
The sync input should sit at nominal 5 VDC and transition to ground
level at a 10% +/1% duty cycle. It should be noted that the
internal oscillator runs at twice the switching frequency, so a
400 kHz sync is needed for 200 kHz operation. On special order,
a sync input at 200 kHz may be obtained. Other frequencies are also
available on special order. Contact MDI's Sales and Marketing Department
for other sync frequencies.
Synchronizing
the power conversion units within an extremely sensitive system
ensures that any noise generation is coincident with the system
clock.
The "sync pin"
must be left open if unused.

|